MAICO MA 52

Portable audiometer Maico MA 52 with two channels, similar to MA 51 but with SISI, DLI, ABLB and Carhart Decay tests.

FEATURES:

  • Portable audiometer with ergonomic design and easy transport
  • SISI, DLI, ABLB and Carhart Decay tests
  • For bone and air conduction and speech audiometry with masking
  • Continuous, pulsed and modulated tones
  • Frequency from 0.125 to 8 KHz in 11 stages until 120 dB
  • With input for CD, cassette and microphone
  • Output RS 232 for PC connection
  • Includes: answer switch, headphone DD45, bone applicator B71, power cable

TECHNICAL DATA:

  • Test signal: Pure, pulsed, modulated tones; speech audiometry with masking
  • Test frequencies: 0.125, 0.25, 0.5, 1, 1.5, 2, 3, 4, 6, 8 KHz
  • Level steps: 5 dB, 2 dB noise free
  • Inputs: CD/cassette, microphones, patient answer switch
  • SISI, DLI, ABLB and Carhart Decay tests
  • Outputs: AC, BC, headphones, free field, headphone monitor, electric output
  • Tracking function
  • Standards:
    • IEC-601-1
    • IEC 645-1 class 4, Directive 93/42/CEE on Medical Devices
  • PC connection by serial RS 232C, 9 pins connector, protocol MAICO
  • Power supply: 100-240V, 50/60Hz 25VA
  • Dimensions: 36 x 46 x 15 cm
  • Weight: 5.8 Kg
  • Standard accessories: Headphones DD45, bone applicator B71, main cable (2 m), patient answer switch, microphone, audiograms

Air conduction:

  • Dynamic range: -10 to 120 dBHL
  • Headphones: DD45

Bone conduction:

  • Dynamic range: -10 to 70 dBHL
  • Bone applicator: B71 with cranial strap
  • Signal mask: Narrow band noise, masked speech noise

Free field:

  • Dynamic range: -10 to 90 dB at 1 m distance

OPTIONAL ACCESSORIES AND SPARE PARTS:

  • Ref. 039-MO8111951   Speaker SBC (2 pcs)
  • Ref. 039-MO8110906   Speaker Canton CD 220/2 (2 pcs)
  • Ref. 039-MO8004229   Cable for speaker Canton CD 220/2 (2 pcs)
  • Ref. 039-MO8010959   Insert microphones Eartone 3A
  • Ref. 039-MO8011233   Answer microphone
  • Ref. 039-MO8110458   Assistant microphone
  • Ref. 039-MO8111857   Monitor microphone
  • Ref. 039-MO8111383   Y cable for assistant microphone
  • Ref. 039-MO8103691   CD player with connection cable
  • Ref. 039-MO8111942   Supplement for delivery with headphone for bone conduction with masking BKH10-3
  • Ref. 039-MO8010806   Headphones TDH 39 instead of DD45

COMPARATIVE CHART MAICO DIAGNOSTIC AUDIOMETERS

MA 41MA 42MA 51MA 52MA 53
Class22221
OutputsAC, input microphone, BC, FF, monitorAC, input microphone, BC, FF, monitorAC, input microphone, BC, FF, monitorAC, input microphone, BC, FF, monitorAC, input microphone, BC, masking signals, FF, line out, monitor
InputsExternal CD play, microphone, response microphoneExternal CD play, microphone, response microphoneExternal CD play, microphoneExternal CD play, microphone2 External CD play, 2 microphones, TB microphone
Frequencies (Hz)125-8000125-8000/20000 (optional)125-8000125-8000125-8000 high tones up to 16000 Hz
Air (dBHL)-10 to 120-10 to 120-10 to 120-10 to 120-10 to 120
Bone (dBHL)-10 to 80-10 to 80-10 to 70-10 to 70-10 to 70
Free field (dBHL)-10 to 95-10 to 95-10 to 90-10 to 90-10 to 90
Level steps (dB)5/2/15/2/15/25/2/15/2/1
Masking signalNBN, SNNBN, WN, SNNBN, SN, externalNBN, SN, externalNBN, SN, external
Test signalsSinus, pulse, wave SD-Card warble, externalSinus, pulse, warble, wave SD-card, externalSinus, pulse, warble, externalSinus, pulse, warble, externalSinus, pulse, warble, external
Voice sourceCD, microphone, waveCD, microphone, waveCD, microphoneCD, microphoneCD, microphone
Special testsTone audiometry, HL, UCL, Assisted, Speech: SRT, WRS, UCL, MHA (optional)Tone audiometry, tone, HL, UCL, MCL, Assisted, SISI, ABLB, Decay, MLB, speech: SRT, WRS, UCL, MHA (optional)SISI, DLI, ABLB, Decay, Stenger, Noise with voiceSISI, DLI, ABLB, Decay, Stenger, Tinnitus Test, Langenbeck
Compatible with NOAHYesYesYesYesYes
Data connectionYesYesYesYesYes
Dimensions (An Al x L)36 x 18.5 x 7.5 cm36 x 18.5 x 7.5 cm36 x 46 x 15 cm36 x 46 x 15 cm36 x 46 x 15 cm
Weight1.5 kg1.5 kg4.6 kg4.6 kg4.6 kg
Special featuresPDF storage, SD or UDB card. Direct printout via USB or Ethernet. More than 1000 patients and 100 sessionsPDF storage, SD or UDB card. Direct printout via USB or Ethernet. More than 1000 patients and 100 sessions1 Hz frequency steps, mixing flexible channels

 

– See more at: http://www.quirumed.com/en/diagnostic-audiometer-ma-52-with-test-sisi-dli-ablb-and-decay.html#sthash.iarkEfVv.dpuf