Precision Made Easy
InnovaStar® is an automatic compact POCT analyzer for the daily practice that delivers result quality comparable to measurements on laboratory analyzers.
Easy to use
No special knowledge and extended training is required to operate the system. Testing is made easy with unit-dose reagents and precalibrated tests. The system is calibrated automatically with parameter cards which come with every test package.
Individual hematocrit correction
InnovaStar® uses the individual hematocrit correction to avoid inaccurate calculations of whole blood glucose into plasma glucose. The instrument measures the individual hemoglobin concentration (hematocrit value and Hb concentration are correlated) of a whole blood sample. The measured hemoglobin value is the basis to generate the individual compensation factor for the calculation of whole blood glucose into plasma glucose for each sample – thus providing true glucose values.
Precise
High-quality reagents from DiaSys, freedom from interference, and a photometer detection unit with outstanding linearity are the guarantee for highest possible precision.
Future-Proof
Currently available are tests for HbA1c, glucose and hemoglobin. The future-oriented multiple-testing principle allows for easy expansion of the test portfolio, e.g. for the early detection of kidney disease.
Performance data
Parameter | HbA1c IS | CRP IS | |
---|---|---|---|
Measuring Range (units selectable) | 3 – 14 %DCCT 9 – 130 mmol/mol | 2 – 160 mg/L (Plasma) 5 – 400 mg/L (Whole Blood) | |
Precision (CV%) | <2% at 6.24% DCCT | 3.1% at 4.11mg/L (Whole Blood) | |
Sample specimen | Whole Blood | Whole Blood / Plasma | |
Sample Volume | Determination of all analytes from 10 µl whole blood | ||
Measuring Time | 6.5 minutes to result | ||
Shelf Life | 18 months | 18 months |
Performance data (continued)
Parameter | Glucose/Hemoglobin | |
---|---|---|
Glucose | Hemoglobin | |
Measuring Range (units selectable) | 15 – 800 mg/dL 0.83 – 44.4 mmol/L | 5 – 25 g/dL |
Precision (CV%) | 1.3% at 125 mg/L | 0.79% at 14.5 g/dL |
Sample specimen | Whole Blood | |
Sample Volume | Determination of all analytes from 10 µl whole blood | |
Measuring Time | 6.5 minutes to result | |
Shelf Life | 18 months |
Barcode Identification | Automatic barcode scan for reagents; optional barcode scanner for samples |
Calibration | Pre-calibrated tests |
Data Storage | 50 results |
Measurement Principle | Photometric / Turbidimetric |
Method Storage | Up to 19 different methods or lots |
EDP Interface | RS232 connection; USB connection via adapter |
Dimensions | 20 cm (W) x 15 cm (H) x 17 cm (D) |
Weight | 4 kg |
Article Number | Description |
---|---|
1 3329 99 10 760 | HbA1c IS, 100 tests |
2 7069 99 10 760 | CRP IS, 100 tests |
2 7069 99 10 761 | CRP IS, 50 tests |
1 2491 99 10 760 | Glucose/Hemoglobin IS, 100 tests |
970113 | 10 x 100 Sample Cups InnovaStar 10/500 |
920709 | 10 x 100 Open End capillaries 10 µl |
970115 | 300 mL System Solution InnovaStar |